Ventilationens betydning for de hygrotermiske forhold i ventilerede tagrum

Oversat titel

Ventilations influence on hygrothermal conditions in ventilated roof space

Forfattere

;

Semester

4. semester

Udgivelsesår

2019

Afleveret

Resumé

Dette projekt undersøger, hvor stor betydning ventilationsraten har for temperatur- og fugtforhold i uopvarmede, ventilerede tagrum, sammenlignet med isoleringstype/-tykkelse og anvendelse af dampspærre, samt hvilken indflydelse dette har på skimmelrisiko. Undersøgelsen er udført i SBi’s testhus fra Projekt DaLo, inddelt i tre sektioner med hver seks adskilte tagrum over forskellige loftkonstruktioner (mineraluld/cellulose i varierende tykkelser, med/uden dampspærre). Én sektion er ventileret efter gældende anbefalinger, mens to sektioner har reduceret ventilation (reduktioner blev verificeret med sporgas efter PFT-metoden). Fra januar til marts blev temperatur og relativ luftfugtighed målt time for time, og træfugt i spærene blev registreret med 7–14 dages mellemrum. Parallelt blev hygrotermiske forhold simuleret i BSim og WUFI, og skimmelrisikoen blev vurderet med MRD-metoden. Målingerne viste, at lavere luftskifte generelt hæver den relative luftfugtighed i tagrummene, og at ventilationsraten har større betydning end isoleringstykkelsen; forskelle mellem mineraluld og cellulose var små, hvilket peger på begrænset fugtbuffering i den observerede periode. Dampspærre gav typisk lavere relativ fugtighed ved lav ventilation, mens vejrforhold (solindstråling, skydække og nattradiation) havde markant indflydelse på temperatur og fugt. Simulationerne gav overordnet forventede resultater, men overestimerede hygroskopien for cellulose, og forskelle til målinger knyttede sig især til vejrdata. MRD-beregninger indikerede lav skimmelrisiko i alle konfigurationer så længe lofterne er lufttætte og tagrummene ventileres, om end risikoen er større ved lavere luftskifte. Den korte måleperiode sidst i vækstsæsonen begrænser muligheden for statistisk sikre konklusioner, særligt om behovet for dampspærre ved cellulose; tendensen peger dog på, at luftskiftet er den mest styrende faktor, og at dampspærrens betydning øges ved lav ventilation.

This study examines how much the air change rate influences temperature and moisture conditions in unheated, ventilated attics compared with insulation type/thickness and the presence of a vapour barrier, and how these factors affect mould risk. The work was carried out in SBi’s test house from Project DaLo, divided into three sections with six separate attic compartments per section above different ceiling assemblies (mineral wool/cellulose in varying thicknesses, with/without a vapour barrier). One section followed current ventilation recommendations, while two sections had reduced ventilation (reductions verified with tracer gas using the PFT method). From January through March, temperature and relative humidity were recorded hourly, and wood moisture in the trusses was measured every 7–14 days. In parallel, hygrothermal behavior was simulated in BSim and WUFI, and mould risk was assessed with the MRD method. Measurements indicated that lowering the air change rate generally raised the relative humidity in the attics, and that air change had a larger effect than insulation thickness; differences between mineral wool and cellulose were small, suggesting limited moisture buffering over the observation period. Vapour barriers typically reduced relative humidity under lower ventilation, while weather (solar gains, cloud cover, and nighttime radiative cooling) strongly affected temperature and humidity. Simulations broadly matched expectations but tended to overestimate cellulose hygroscopicity, and mismatches to measurements were mainly tied to weather data. MRD calculations showed a low mould risk across configurations provided the ceilings are airtight and the attics are ventilated, although risk increases as air change decreases. The short monitoring period late in the mould growth season limits firm statistical conclusions, particularly regarding the need for a vapour barrier with cellulose; the overall tendency points to air change as the dominant factor, with the vapour barrier becoming more important at low ventilation.

[Dette resumé er genereret med hjælp fra AI direkte fra projektet (PDF)]