AAU Studenterprojekter - besøg Aalborg Universitets studenterprojektportal
A master programme thesis from Aalborg University

Energioptimering af bevaringsværdigt hus fra 1890 med fokus på øget termisk komfort

[Energy optimization of a heritage home from 1890 with a focus on improved thermal comfort]

Forfatter(e)

Semester

4. semester

Uddannelse

Udgivelsesår

2023

Afleveret

2023-06-08

Antal sider

125 pages

Abstract

Rapporten har til formål at afdække tiltag der kan forberede termisk komfort og energioptimere Fogedgården i Bondebyen. Konstruktionsløsninger udarbejdes som dele af de kommende renoveringsløsninger af husets stueplan. Selve renoveringen forventes udført i den nærmeste fremtid. Huset er bevaringsværdigt, og er vurderet til værdi 3 efter SAVE-metoden, flere af træerne er også tildelt bevaringsværdig status, hvorfor fremtidigt arbejde skal tage hensyn til både generelle bevaringsværdier og lokalplanen for Bondebyen. Derfor er efterisolering udelukkende begrænset til indvendig efterisolering. Huset gennemgik en større renovering i 1980’erne. Huset er grundmuret med et træbjælkelag og stråtag. Indervæggene er af porebeton, og ydervægge er fuldmuret 1-stensvægge med 95 mm forsatsvægge. Vinduer er de originale med eftermonterede forsatsruder. Erfaringsmæssigt kan indvendig efterisolering af denne type konstruktion være problematisk at udføre. Derfor opstilles der fire forskellige løsningsforslag for at forbedre betingelser for stuens termiske komfort. Forslagene er en kombination af at de eksisterende vinduer renoveres og energioptimeres med eller uden etablering af ny dampspærre samt efterisolering af eksisterende forsatsvæg. Effekten af den indvendige efterisolering og vinduesoptimering afdækkes teoretisk med beregningsprogrammerne WUFI og HEAT2 for at afklare eventuelle ændrede situationer som kan medføre kritiske fugtforhold, i form af kondens og skimmelsvampevækst. På baggrund af de udførte beregninger kan det konkluderes, at indvendig efterisolering med yderligere 45 mm anbefales, såfremt en ny dampspærre etableres så den tilsluttes de tilstødende bygningsdeles tæthedsplan. Dampspærren skal være beskyttet af installationslaget for at sikre mod fremtidige gennembrydninger. Det anbefales at de eksisterende vinduesrammer renoveres og en ny, koblet ramme med enkeltlagsglas eftermonteres.

The report aims to identify measures that can enhance thermal comfort and optimize energy efficiency for Fogedgården in Bondebyen. Construction solutions are being developed as part of the upcoming renovation of the ground floor of the house. The renovation itself is expected to be carried out in the near future. The house is of historical value and has been assessed as Grade 3 according to the SAVE method. Several trees on the property have also been designated as having historical value, which means that future work needs to consider both general preservation values and the local plan for Bondebyen. Therefore, solutions including added insulation are limited to internal application only. The house underwent a major renovation in the 1980s. It has a masonry foundation and walls, timber crossbeams and a thatched roof. The interior walls are made of autoclaved aerated concrete, and the exterior walls consist of solid, single-layer thick brick walls with secondary walls with 95 mm insulation installed internally. The windows are original and have secondary windows installed internally as a supplement. Based on experience, insulating this type of construction internally can be challenging to execute without creating moisture risks. Therefore, four different solution proposals are presented to improve thermal comfort in the living room. The proposals involve a combination of renovating and optimizing the existing windows, with or without the installation of a new vapor barrier, as well as insulating the existing secondary walls. The effect of the internal insulation and window optimization is assessed theoretically using the calculation programs WUFI and HEAT2 to identify any potential changes that could lead to critical moisture conditions, such as condensation and mold growth. Based on the calculations performed, it can be concluded that internal insulation with an additional 45 mm thickness is recommended if the new vapor barrier is installed and properly sealed to the adjacent building components' air barrier. The vapor barrier should be protected by the installation layer to prevent future breaches. It is also recommended to renovate the existing window frames and install a new coupled sash with single glazing.

Emneord

Dokumenter


Kolofon: Denne side er en del af AAU Studenterprojekter — Aalborg Universitets studenterprojektportal. Her kan du finde og downloade offentligt tilgængelige kandidatspecialer og masterprojekter fra hele universitetet fra 2008 og frem. Studenterprojekter fra før 2008 kan findes i trykt form på Aalborg Universitetsbibliotek.

Har du spørgsmål til AAU Studenterprojekter eller Aalborg Universitets forskningsregistrering, formidling og analyse, er du altid velkommen til at kontakte VBN-teamet. Du kan også læse mere i AAU Studenterprojekter FAQ.