Abstract
Rapporten omhandler implementering af realtidsstyring med DORA metoden, som er en model prædiktiv styring, i Kolding afløbssystem, hvor der allerede er implementeret regelbaseretstyring. Klimaændringerne øger belastningen på afløbssystemerne. Derfor undersøges det, om det er muligt at reducere aflastninger med spildevand til recipienter, ved at ændre styringsmetoden. En screening af styringspotentialet til Kolding afløbssystem, har vist at der er potentiale for at reducere overløbsvolumen yderligere i forhold til den allerede implementerede styringsstrategi. Hvor det er fundet at der potentiale for reduktion af overløbsvolumen i systemet. Ved implementering af DORA styring er det fundet at det er muligt at reducere overløbsvolumen i systemet med 9 \% over et helt år, baseret på hændelser fra 2012. Reduktionen har samme størrelsesorden som stigning i årsmiddelnedbør frem mod år 2100 som følge af klimaændringer. Det er forsøgt at beskytte specifikke recipienter ved brug af vægtning af overløbsbygværker i systemet. Resultaterne her er af skiftende karakter. Da vægtningsfordelingerne i projektet er lavet uden at tage hensyn til systemets opbygning, og det fører til at nogle vægtningsfordelinger fører til forværringer, sammenlignet med statussituationen.
This report is about the implementation of realtime control with the DORA method, which is a model predictive control scheme, in Kolding sewer system, where a rulebased control scheme have already been implemented. Climate change increases the load on the sewer systems. Therefore this report investigates if it is possible to reduce combined sewer overflows (CSO) to the recipients, by changing the control scheme. A screening of the potential for reducing CSO in Kolding sewer system, has shown that there is potential to reduce CSO even more than the current control scheme. Where it has been found, that there is potential for reduktion of CSO, by changing the control scheme. By implementing the DORA control scheme it has been found that it is possible to reduce CSO volume in the system by 9 % over a whole year, based on rain events from 2012. The reduction is in the same order of magnitude as the increase in yearly mean precipitation before year 2100 as a result of climate change. It has been attempted to protect specific recipients by using weights on CSO structures in the system. The results of this are mixed. As the weight matrices used in the project, have been made without taking the geometry of the system into account, and that means some weight matrices leads to worsenings, compared to the current situation.
Emneord
Realtidsstyring ; Styring ; DORA ; Kolding
Kolofon: Denne side er en del af AAU Studenterprojekter — Aalborg Universitets studenterprojektportal. Her kan du finde og downloade offentligt tilgængelige kandidatspecialer og masterprojekter fra hele universitetet fra 2008 og frem. Studenterprojekter fra før 2008 kan findes i trykt form på Aalborg Universitetsbibliotek.
Har du spørgsmål til AAU Studenterprojekter eller Aalborg Universitets forskningsregistrering, formidling og analyse, er du altid velkommen til at kontakte VBN-teamet. Du kan også læse mere i AAU Studenterprojekter FAQ.